Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Alexandria.

The Engineering Groupe
(703) 670-0985
13580 Groupe Drive, Suite 200
Woodbridge, VA

Data Provided by:
LHI & Design
(703) 401-3141
6537 Riefton ct.
Alex., VA
Services
Architectural plans and permits, constructions and design

Kilpatrick Contractor
(571) 389-0798
5604 Vine St
Alexandria, VA
 
LHI & Design
(703) 401-3141
6537 Riefton Ct
Alexandria, VA
Services
Architectural design / residential construction
Prices and/or Promotions
Free design plus permit drawings if awarded construction contract

Sigal Construction Corporation
(703) 302-1500
2231 Crystal Dr.
Washington, DC
 
Probuilt Deck And Fence
(301) 474-3550
5110 Roanoke Place, Suite 106
College Park, MD

Data Provided by:
Agua-Man
(571) 214-8339
3305 king street
alexandria, VA
 
LHI DESIGNS
(703) 401-3141
6537 riefton ct.
alexandria, VA
 
Bozzuto Construction
(703) 379-2402
4220 Campbell Ave
Arlington, VA
 
Ace Handyman ProHome Improvements
(703) 260-1786
6000 Amherst Ave
Springfield, VA
Services
General Contractor, Handyman, Residential Painter, Handyman Service, Bathroom Remodeling, Tile Work
Awards
General Contractor, Handyman, Residential Painter, Handyman Service, Bathroom Remodeling, Tile Work
Membership Organizations
General Contractor, Handyman, Residential Painter, Handyman Service, Bathroom Remodeling, Tile Work
Prices and/or Promotions
General Contractor, Handyman, Residential Painter, Handyman Service, Bathroom Remodeling, Tile Work

Data Provided by:

Flashing Factors

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Local Events

Archiving 2009
Dates: 5/5/2009 – 5/8/2020
Location:
Crystal City Hilton Arlington
View Details